DN0100C 40 Amps 3 Pole MCCB
Minimum Order Quantity: 1 Piece
| Rated Current | 40 A |
| Breaking Capacity | 25 kA |
| Poles | 3 Pole |
| Frame Size | 100 A Frame |
| Trip Unit Type | Electronic |
| Mounting Type | Panel Mount |
| Current Rating | 32A |
| Number of Poles | 3 Pole |
The L&T DN0-100C 40 Amp MCCB is a 3-pole, molded case circuit breaker with a thermal magnetic trip unit, offering adjustable overload and short-circuit protection within its frame for heavy-duty electrical applications
Additional Information:
- Production Capacity: 10
- Delivery Time: SAME DAY
DU 100D 50 Amps 4 Pole MccB
Minimum Order Quantity: 1 Piece
| Poles | 4 Pole |
| Current Rating | 63A |
| Breaking Capacity | 18kA |
| Frame Size | 100 A Frame |
| Trip Unit Type | Electronic |
| No. of Poles | 4 Poles |
| Number of Poles | 4 Pole |
| Country of Origin | Made in India |
An L&T (now Lauritz Knudsen) DU100D 50 Amp FB MCCB is a four-pole (FB stands for "Four-Pole") molded case circuit breaker for protecting electrical circuits from faults. It has a frame size capable of holding up to 100 amps but is equipped with a 50-amp thermal-magnetic trip unit. It is designed for industrial, commercial, and residential applications.
DN0125D 125 AMP MCCB
Minimum Order Quantity: 1 Piece
| Poles | 4 Pole |
| Current Rating | 125A |
| Breaking Capacity | 36kA |
| Frame Size | 125 A Frame |
| Trip Unit Type | Electronic |
| Mounting Type | Plug In |
| Standard | IEC 60947-2 |
| Operation Type | Handle |
| Accessories | Auxiliary Contact |
| Application | Sub Main Panel |
| Number of Poles | 4 Pole |
| Country of Origin | Made in India |
The L&T DN0-125D MCCB is a high-performance Molded Case Circuit Breaker with a 125 Amp current rating, 415V AC voltage, and 36kA breaking capacity
Additional Information:
- Delivery Time: SAME DAY
DN2-250D 200AMP MCCB L&T
Minimum Order Quantity: 1 Piece
| Breaking Capacity | 36 kA |
| Frame Size | 250 A Frame |
| Trip Unit Type | Electronic Trip |
| Mounting Type | Panel Mount |
| Number of Poles | 4 Pole |
| Country of Origin | Made in India |
| Rated Current | 250 A |
| Current Rating | 200A |
The L&T DN2-250D 200A MCCB is a 4-pole Molded Case Circuit Breaker with a 200A rating, designed for industrial use to protect electrical circuits from overloads and short circuits
Additional Information:
- Production Capacity: 20 PIECES
- Delivery Time: 1-3 DAYS
DH 125 Three Pole MCCB L&T
Minimum Order Quantity: 5 Piece
| Rated Current | 125 A |
| Breaking Capacity | 25 kA |
| Number Of Poles | 3 Pole |
| Frame Size | 100 A Frame |
| Trip Unit Type | Electronic Trip |
| Mounting Type | Panel Mount |
| Voltage Rating | 415 V |
| Protection Type | Overload |
| Series | D Line |
Additional Information:
- Production Capacity: 10
- Delivery Time: SAME DAY
Motor Protection Circuit Breaker
| Setting Range | 0.1–0.16 A |
| Rated Operational Current | 1.6 A |
| Phase | Single Phase |
| Mounting Type | DIN Rail |
| Trip Class | Class 10 |
| Breaking Capacity | 25 kA |
| Control Voltage | 230 V AC |
| Auxiliary Contacts | No Aux |
| Application | Pump Motor |
| Standards | IEC 60947-4 |
MPCB GV2 ME21 Schneider
Minimum Order Quantity: 1 Piece
| Series | GV2 |
| Setting Range | 12-23A |
| Current Rating | 25A |
| Rated Operational Current | 25 A |
| Phase | Single Phase |
| Mounting Type | Panel Mount |
| Trip Class | Class 10 |
| Breaking Capacity | 25 kA |
| Number of Poles | Triple Pole |
| Country of Origin | Made in India |
The Schneider GV2ME21 is a 3-pole motor circuit breaker from the TeSys Deca range. It provides thermal-magnetic protection and manual on/off control via push-buttons for three-phase AC motor applications.
MPCB GV2 ME16 Schneider
Minimum Order Quantity: 1 Piece
| Series | GV2 |
| Setting Range | 9-14 |
| Current Rating | 9-14 AMPS |
| Rated Operational Current | 10 A |
| Phase | Single Phase |
| Mounting Type | Panel Mount |
| Trip Class | Class 10 |
| Breaking Capacity | 25 kA |
| Number of Poles | Double Pole |
| Country of Origin | Made in India |
The Schneider GV2ME16 is a 3-pole motor circuit breaker from the TeSys Deca series, designed for industrial applications to provide manual motor control and thermal-magnetic protection
Additional Information:
- Production Capacity: 15 PIECES
- Delivery Time: SAME DAY
MPCB GV2 ME14
Minimum Order Quantity: 1 Piece
| Series | GV2 |
| Current Rating | 10A |
| Setting Range | 6–10 A |
| Phase | Single Phase |
| Mounting Type | DIN Rail |
| Trip Class | Class 10 |
| Control Voltage | 230 V AC |
| Application | Pump Motor |
| Standards | IEC 60947-4 |
| Country of Origin | Made in India |
The Schneider Electric GV2ME14 is a 3-pole, thermal-magnetic motor circuit breaker from the TeSys GV2 series, designed to protect 3-phase motors up to 3-4 kW by providing overload and short-circuit protection with a 6-10A adjustable thermal setting
Additional Information:
- Delivery Time: SAME DAY
63A 4 Pole MCB L&T
Minimum Order Quantity: 10 Piece
| Phase | Three Phase |
| Number Of Poles | 4 pole |
| Tripping Curve | C |
| Rated Current | 63 A |
| Voltage | 415 V |
| Breaking Capacity | 10 kA |
| Certification | IS/IEC 60898-1 |
| Series | Exora |
| Temperature | 50 degree c |
The L&T 63A Four Pole (FP) MCB is a robust, high-performance miniature circuit breaker designed for 3-phase, 415V AC electrical systems. It provides superior protection against overloads and short circuits using C-curve characteristics, making it ideal for industrial motors, commercial, and residential applications.
Rccb Residual Current Circuit Breaker
| Rated current | 63 A |
| Sensitivity | 100 mA |
| Pole | 2 Pole |
| Rated voltage | 230 V |
| Tripping type | AC |
| Breaking capacity | 10 kA |
| Brand | L&T |
| Mounting | DIN Rail |
| Standard | IEC 61008 |